CHAPTER2 SNMP Trap Alarms
MSBR | SNMP Alarms
Table 2-36: acAnalogPortSPIOutOfService
Alarm acAnalogPortSPIOutOfService
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.46
Default
Severity
Major
Source
Varbind
Text
System#0/analogports#<n>, where n is the port number
Event Type physicalViolation
Probable
Cause
equipmentMalfunction
Alarm
Severity
Condition Text Corrective Action
Major Analog port
has gone
out of
service
"Analog
Port SPI out
of service"
No corrective action is required.
The device shuts down the port and
activates it again when the Serial
Peripheral Interface (SPI) connection
returns.
Cleared Analog port
is back in
service
- -
Analog Port High Temperature Alarm
Table 2-37: acAnalogPortHighTemperature
Alarm acAnalogPortHighTemperature
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.47
Default Severity Major
Source Varbind Text System#0/analogports#<n>, where n is the port number
Event Type physicalViolation
Probable Cause equipmentMalfunction
Severity Condition Text Corrective Action