CHAPTER2 SNMP Trap Alarms
MSBR | SNMP Alarms
Table 2-36: acAnalogPortSPIOutOfService
Alarm acAnalogPortSPIOutOfService
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.46
Default
Severity
Major
Source
Varbind
Text
System#0/analogports#<n>, where n is the port number
Event Type physicalViolation
Probable
Cause
equipmentMalfunction
Alarm
Severity
Condition Text Corrective Action
Major Analog port
has gone
out of
service
"Analog
Port SPI out
of service"
■ No corrective action is required.
■ The device shuts down the port and
activates it again when the Serial
Peripheral Interface (SPI) connection
returns.
Cleared Analog port
is back in
service
- -
Analog Port High Temperature Alarm
Table 2-37: acAnalogPortHighTemperature
Alarm acAnalogPortHighTemperature
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.47
Default Severity Major
Source Varbind Text System#0/analogports#<n>, where n is the port number
Event Type physicalViolation
Probable Cause equipmentMalfunction
Severity Condition Text Corrective Action
- 48 -