CHAPTER2 SNMP Trap Alarms
MSBR | SNMP Alarms
NQM High Jitter Alarm
Table 2-48: acNqmJitterAlarm
Alarm acNqmJitterAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.90
Description The alarm is sent when the device detects high jitter towards the
Network Quality Monitoring (NQM) probe destination.
Default Severity Minor
Alarm Source Board#%d/NqmSender#%d
Event Type CommunicationsAlarm
Probable Cause The alarm is sent when high jitter is detected towards the NQM
probe destination thresholdCrossed.
Alarm Severity Condition Text Corrective Action
Minor - Detected high
Jitter towards
NQM probe
destination
To correct high jitter:
Test with traceroute.
Contact your
Internet Service
Provider (ISP) with
traceroute results.
Implement Quality
of Service (QoS).
Note: There's no simple
solution for high jitter. A
systemic level solution
may be required.