CHAPTER2 SNMP Trap Alarms
MSBR | SNMP Alarms
Alarm acProxyConnectionLost
Proxy Set are online ip:<IP
address>:<port #>
Proxy Set ID <ID>"
Controller Failure Alarm
Table 2-16: acBoardControllerFailureAlarm
Alarm acBoardControllerFailureAlarm
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.9
Description The alarm is sent in the following scenarios:
For Mediant 500L, Mediant 800, and Mediant 1000: Physical FXO port
is up or down (Out-of-Service or OOS). The FXO line can be down due
to, for example, port disconnected or insufficient current and voltage.
(Syslog message event is ANALOG_IF_LINE_DISCONNECTED.)
Physical BRI or PRI (E1/T1) port is up or down (OOS).
Proxy is not found or registration fails. In such a case, the device's
routing table may be used for routing instead of the Proxy.
Connection to the Proxy is up or down.
Failure in TDM-over-IP call - transparent E1/T1 without signalling.
Connection to the Proxy Set associated with the trunk/line is
up/down.
Failure in server registration for the trunk/line.
Failure in a Serving IP Group for the trunk.
Failure in a Proxy Set.
Default
Severity
Major
Event Type processingErrorAlarm
Probable
Cause
softwareError (46)
Severity Condition Text Additional Information
Major Failure in a Proxy Set "Proxy Set ID n"
Where n represents
- 25 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MSBR Series and is the answer not in the manual?

AudioCodes MSBR Series Specifications

General IconGeneral
BrandAudioCodes
ModelMSBR Series
CategorySecurity System
LanguageEnglish

Related product manuals