CHAPTER2 SNMP Trap Alarms
MSBR | SNMP Alarms
Alarm acBoardOverloadAlarm
available CPU
resources
remaining.
not running.
c. If the system is con-
figured correctly,
reduce traffic.
Cleared The overload
condition passed
"System CPU
overload condition -
IdleUtilization
percentage=%"
-
Administration Status Change Alarm
Table 2-18: acgwAdminStateChange
Alarm acgwAdminStateChange
OID 1.3.6.1.4.1.5003.9.10.1.21.2.0.7
Description The alarm is sent when Graceful Shutdown commences and ends.
Default
Severity
Major
Event Type processingErrorAlarm
Probable
Cause
outOfService (71)
Severity Condition Text Corrective Action
Major Admin
state
changed to
shutting
down
"Network element admin
state change alarm:
Gateway is shutting down.
No time limit."
■ No corrective action is
required.
■ A network administrator
took an action to
gracefully lock the
device.
Major Admin
state
changed to
locked
"Locked" ■ No corrective action is
required.
■ A network administrator
took an action to lock
the device, or a graceful
lock timeout occurred.