Document No.: E4.08.09 E4.08.09 : AE_xx_000
Revision: 13 9 : 00
Page: 85 of 89
Copyright © 2019, Austro Engine GmbH
Dept.: Electric/Electronic
10.5.4 Unsuccessful Completion
After an uninterrupted software update session the AE300-Wizard will perform a number of
post flash checks (checksums, flash memory related FCM entries, consistency of ECU-A and
ECU–B, etc.) to verify success of the update session on both ECUs.
If these checks reveal any problems or inconsistencies, a RED MESSAGE BOX will inform
the maintenance technician about the detected problem.
Depending on the type of problem detected by the AE300-Wizard, the information in the
message box will either suggest a manual restart of the software update by the maintenance
technician, if this is a viable option, or will ask the technician to call Austro Engine for sup-
port in determining further actions.
If (i.e. after several unsuccessful software update attempts) the EECU is in a state where it
does not respond to queries from the AE300-Wizard anymore and therefore the pre flash
conditions cannot be verified anymore – no further software update attempts will be allowed
by the AE300-Wizard and it will ask the maintenance technician to call Austro Engine for help
to solve the situation.