Autonics TK4L - Parameter 1 Setting Group [ PAR1 ]

Autonics TK4L
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 Setting Group Parameter Description
110 © Copyright Reserved Autonics Co., Ltd.
7.3 Parameter 1 Setting Group [ PAR1 ]
Parameter Description Setting Range Unit
Factory
Default
R-S
RUN_STOP
Control Output
Run/Stop
RUN
/
STOP
-
RUN
SV-N
Multi SV No.
Multi SV number
selection.
SV-0
/
SV-1
/
SV-2
/
SV-3
-
SV-0
CT-A
Heater Current
Monitoring
Heater current
monitoring.
00.0
to
50.0
(display range)
A
-
AL1.L
Alarm1_Low
Alarm output 1's
lower limit setting.
Offset Alarm: -F. S.
to F.S .
Absolute Value
Alarm: Within
display range.
/℉
/-
1550
AL1.H
Alarm1_High
Alarm output 1's
upper limit setting.
1550
AL2.L
Alarm2_Low
Alarm output 2's
lower limit setting.
1550
AL2.H
Alarm2_High
Alarm output 2's
upper limit setting.
1550
SV-0
SV-0 Setting
Value
SV-0 setting.
Between
L-SV
and
H-SV
/℉
/-
0000
SV-1
SV-1 Setting
Value
SV-1 setting.
Between
L-SV
and
H-SV
/℉
/-
0000
SV-2
SV-2 Setting
Value
SV-2 setting.
Between
L-SV
and
H-SV
/℉
/-
0000
SV-3
SV-3 Setting
Value
SV-3 setting.
Between
L-SV
and
H-SV
/℉
/-
0000