Setting the Start Encode Position
This option only appears in the Advanced Setup menu. The start encode position is only
used in non-stop encode mode. The printer uses this initial starting position to look for
the RFID inlay to program while moving the supply. The range is 10 to 2000. The default
is 100.
The start encode position is measured from the leading edge of the supply to the
beginning of the RFID inlay encoding area in 0.01 inches.
The start encode position must “lead” (be before) the first TID position; otherwise, error
737 occurs.
Use the RFID Printer Setup Utility to determine the start encode position then enter the
value at the printer.
Select To
Decrease the setting.
Increase the setting.
Press 1 to toggle the amount (1, 10, or 100).
Start Encode Position
Trailing Edge
0,0 point