29
2PRODUCT DESCRIPTION
2.3 OPERATING MODES
ALS
20x
256
2.3.1 Dispensing mode
This is the operating mode of the unit when switched
on. You can carry out the functions listed in the sections
below.
If text such as ‘Prof 5 xxxxxxxx’ is displayed
instead of ‘ONLINE’:
– The ‘xxxxxxxx’ product profile (memory
location 5) is activated.
– For more information, see the ‘Using product
profiles’ section.
Stopping /Continuing the dispensing
Stopping the dispensing:
Press the button.
– The dispenser stops.
– Displayed text:
1) Second line = scroll text.
Continuing the dispensing:
Press the button.
Changing the counter reading
Set the counter reading using the MACHINE SETUP >
Dispense counter function.
Resetting the counter reading
Set MACHINE SETUP > Disp. Cnt. Reset = „Yes“.
Starting the unit in configuration mode
To start the unit in configuration mode:
Set MACHINE SETUP > Turn-on mode = „Offline“.
Counting labels backwards
To count dispensed labels backwards from a starting
value to zero:
Set LABEL SETUP > Stop count. mode to „Enabled“.
Use the LABEL SETUP > Label stop quan. function to
define the starting value.
ONLINE
Stopped . press ^ key to start
1
[24 Control panel in dispensing mode (292 labels dispensed)
A Explanation of buttons in dispensing mode
+
+
–
–
ON
STATUS
Online
292
Labels
A
2.3 OPERATING MODES