36
2PRODUCT DESCRIPTION
2.4 FUNCTION DESCRIPTIONS
ALS
20x
256
„x labels/start“: Each start signal causes printing of
x labels; x = [2…20]
x > 3: The distance of all following labels after the
2nd label matches the value set in LABEL SETUP >
Label 2 offset.
Label 2 offset function:
– Only appears if LABEL SETUP > Multi label mode =
„x labels/start“.
– Defines the distance of the 2nd label and of all
following labels, if x > 3 (see LABEL SETUP > Multi label
mode function). The distance is measured from the
front label edge of the preceding label.
– Setting range: [x…9999.9] mm; Default: x, with
x = LABEL SETUP > Label pitch.
Label 3 offset function:
– Only appears if LABEL SETUP > Multi label mode =
„3 labels/start“.
– Defines the distance of the 3rd label for the
LABEL SETUP > Multi label mode function (see above).
The distance is measured from the front label edge
of the preceding label.
– Setting range: [x…9999.9] mm; Default: x, with
x = LABEL SETUP > Label pitch.
Miss. label tol. function:
– Missing label tolerance
– The maximum permissible number of successive
missing labels on the label strip
– Setting range: [0…10] mm; default: 1
– See chap. “Missing labels” on page 52.
Stop count. mode function:
– Settings: [Enabled, Disabled]
Enabled: The dispense counter counts down from
the value set in LABEL SETUP > Label stop quan. When
the counter reaches 0, no further labels are
dispensed.
Disabled: The labeller counts up, i.e. each label
dispensed increases the counter reading.
Label stop quan. function:
– After this amount of dispensed labels, the dispenser
stops
– Function only appears, if LABEL SETUP > Stop count.
mode = „On“
– Setting range: [0…99999]; default: 0
2.4.4 MACHINE SETUP menu
Store prod.prof. function:
– Storing a product profile, see chap. “Storing a
product profile” on page 54.
Del. prod.profil function:
– Deleting a product profile, see chap. “Deleting a
product profile” on page 55.
Dispense counter function:
– Enables dispense counter (displayed during
labelling) to be adjusted by pressing the and
keys.
Disp. Cnt. Reset function:
– Settings: [No, Yes]
Yes: Dispense counter is set to zero.
No: Dispense counter is not set to zero.
Turn-on mode function:
– Mode the machine is in after being switched on
– Settings: [Online, Offline, Standalone]
Online: Labelling mode
Offline: mode for adjusting settings
Standalone: This mode is used for loading
firmware or configurations from CF card.
Language function:
– Language of display text
– Settings: [German, English, French, Spanish,
Dutch, Danish, Italian, Polish, Turkish, Russian]
Materialend err function:
– Refers to the internal OD control.
– Settings: [Off, „Mat.diam < x mm“]
– Setting range for x = [40,0…500,0]
– Default setting: x = 60
Deactivating the function:
Set x < 40.
Re-activating the function:
Press the key.
Defines the diameter threshold for the material roll.
If the (calculated) material roll diameter is below the
threshold value, the following status message
appears:
Status num: 5071
Material end unw