6.1.3 List of error messages
Status Status text Cause Action to take
5000 Bus device – Device at I
2
C Bus cannot be
contacted.
– In most cases, this message appears
as the first in a series of two or three
messages which narrow down the
error more precisely.
Delete the message by pressing the
-key.
Switch the machine off, wait 30
seconds and switch it back on.
If the error message appears
repeatedly, call in a servicing
technician.
5001 No gap found – Material end, if no outer diameter
(OD) control is activated.
– The maximum limit for missing labels
was exceeded (LABEL SETUP > Miss.
label tol.).
– The machine is not correctly set for
the type of label (MACHINE SETUP >
Label sens. type).
– Label length is not correctly set
(LABEL SETUP > Label pitch).
– Photoelectric label sensor is dirty.
– Photoelectric label sensor is
incorrectly positioned.
– Photoelectric label sensor is not
connected correctly.
– Photoelectric label sensor is
defective.
– Rotary encoder is not adjusted
correctly.
Check the points listed above and
correct if necessary.
Press the key to confirm the
error message.
5002 Material end – Material end (if the internal OD-
control is activated).
Insert new label roll.
5030
5031
MotorProtectFeed
MotorProtectRew.
– (ALS 256) Dust filter liner exhausted.
This leads to overheating the
machine.
– (ALS 20X) Voltage selection switch
set faulty.
– There are some more possible
causes, which require a qualified
service technician to cure.
Renew the dust filter liner. Let the
machine cool down
Check setting of the voltage
selectioin switch.
Switch the machine off, wait 30
seconds and switch it back on.
If none of the above listed actions is
successful, search for technical
assistance.
5071 Material end unw – Occurs during operation with
activated internal OD control.
– The message appears, if the material
roll diameter has reached the critical
value (setable by MACHINE SETUP >
Materialend err).
Replenish the material roll .
[68] List of error messages