2PRODUCT DESCRIPTION
2.3 OPERATING MODES
ALS
20x
256
GB
Online settings
The machine is in dispensing mode.
To switch to the online settings mode:
Press the button.
The display shows the dispensing speed [25A] and
the start offset [25C].
The button assignments are as shown on the
buttons.
You can increase (‘+’ button) or lower (‘–’ button)
both settings in the dispensing mode [25D].
Dispensing speed:
Setting range:
ALS 204: [1.0…40.0] m/min
ALS 206: [1.0…30.0] m/min
ALS 256: [1.0…50.0] m/min
Display fix: The dispensing speed is constant.
Display var: The dispensing speed automatically
adjusts to the speed of the conveyor belt (‘speed
adaption’).
Start offset:
Setting range: [0.0…999.9] mm
The start offset indicates the distance between the
product sensor and the dispensing edge.
Dispensing manually
To manually trigger the dispensing of individual
labels:
Press the button.
Dispensing speed: As specified in the setting (see
above).
To switch back to dispensing mode:
Press the buttons + .
[25 Control panel in the online settings mode
A Dispensing speed display (here: 12.2 m/min constant)
B Dispense label button
C Start offset display (here: 0 mm)
D Explanation of buttons in online settings mode
E Button to lower dispensing speed
F Button to increase dispensing speed
G Button to lower start offset
H Button to increase start offset
+
+
ON
STATUS
Speed
12.2 fix
Offset
0.0
ABC
D
EFGH

Table of Contents