51
4OPERATION
4.2 CONFIGURATION AND MONITORING
ALS
20x
256
GB
4.2.2 Monitoring functions
While in dispensing mode, an electronic controller
monitors the following functions:
Material end / Roll diameter
(OD = outer diameter)
To enable a quick renewal of the material roll, the
machine can alarm the operator before the end of the
material roll is reached. This provides the OD-control,
which is available in two versions:
Internal OD-control
The machine control elaborates the signals coming
from two sensors, which are integrated into the
material unwinder.
External OD-control (accessory)
A light barrier attached to the material unwinder is
triggered, if the roll OD falls below a certain value.
Depending on the configuration and setting of the
machine, different messages appear in case of material
end or the roll diameter falling below the critical value:
[59] Messages for monitoring label stock.
1) If no rotation of the unwinder was registered during 600mm of material
feeding.
2) If MACHINE SETUP > Materialend err = „Mat.diam < x mm“
3) If MACHINE SETUP > Ext. OD sensor = „Warning“
4) If MACHINE SETUP > Ext. OD sensor = „Error“
If a warning occurs:
Labelling operation is continued.
Press the button, to delete the warning.
Prepare for inserting a new material roll.
Material end Critical OD reached
Error message Warning Error message
No OD-control Status num: 5001
No gap found
none none
Internal OD-control
Status num: 5072
1,2
Material end unw
ONLINE
Material low
Status num: 5071
2
Material end unw
External OD-control none
ONLINE
3
OD sensor warn.
Status num: 5111
4
OD sensor error

Table of Contents