6OPERATIONAL FAILURES
6.1 STATUS MESSAGES
ALS
20x
256
GB
6.1.1 Types of status messages
Error messages
When an error occurs, the machine stops immediately
and displays an error message on the control panel.
Error messages are displayed as follows:
[66] An example of an error message:
5144 = status number; this number makes it easier to identify the
message.
‘Rewinder init’ = status text; a brief description of the error.
Error messages that are not described here may only
be resolved by a qualified service technician.
When an error occurs that is not described here:
Press the button to delete the message.
Switch the device off, wait 30 seconds and then
switch it on again.
If the error reoccurs:
Request a service technician.
Error messages that are not mentioned here
are described in the service manual.
Warnings
Warnings indicate less severe status than error
messages. The labelling is not interrupted by a
warning.
Warning format:
[67] Example of a warning:
„Materialend warn.“ = Warning text; a short description of what
has caused the warning.
Setting back a warning:
Press the key (works earliest with firmware
versions > 1.10).
6.1.2 List of warnings
Status num: 5144
Rewinder init
ONLINE
Material low
Displayed text Meaning
Productstartwarn New start signal during the
dispensing operation.
Or:
Several missing labels on the
web, which can not be
compensated.
APSF speed
warn.
The conveyor speed
exceeded the max. speed
of the dispenser.
OD sensor warn. External OD-control:
Critical material roll diameter is
reached.
Material low Internal OD-control:
Critical material roll diameter is
reached.
Toomany
products
Too many products
between sensor and
dispensing edge.
Rew. stop warn The material rewinder
was switched off by the
operator.
Tandem Synch. Communication between master
and slave machine is not working.
The warning can for example
show up shortly after switching the
machine on, when the
communication between the
machines is not yet established. If
the communication is still
established within 5 minutes after
the warning showed up, the
warning will disappear, otherwise,
after the 5 minutes are over, the
error message
„Tandemsynch.init“ will appear,
see
5147 on page 7. The
warning has the same causes as
the error message.
6 OPERATIONAL FAILURES