2PRODUCT DESCRIPTION
2.4 FUNCTION DESCRIPTIONS
ALS
20x
256
An additional material end error is caused, if no
unwinder rotation is detected during at least 600 mm
of material feeding:
Materialend warn function:
– Refers to the internal OD control.
– Settings: [Off, „Mat.diam < x mm“]
– Setting range for x = [40,0…500,0]
– Default setting: x = 80
Deactivating the function:
Set x < 40.
Re-activating the function:
Press the key.
Defines the diameter threshold for the material roll.
If the (calculated) material roll diameter is below the
threshold value, the following warning appears:
Rewinder full function
Defines the maximum permissible diameter of the
wound backing paper on the backing paper
rewinder. If the diameter is exceeded, the following
status message appears:
– Setting range: [50…500] mm; Default setting:
202 mm
Status num: 5072
Material end unw
ONLINE
Material low
Status num: 5064
Rewinder full