Partially-Filled Pipe Situations
In some locations, the process pipe may be momentarily only partially filled. Examples include: lack of back pressure,
insufficient line pressure and gravity flow applications.
To eliminate these situations:
• Do not install the meter at the highest point of the pipeline.
• Do not install the meter in a vertical, downward flow section of pipe.
• Always position the ON/OFF valves on the downstream side of the meter.
FLOW
FLOW
FLOW
WRONG
FLOW
RIGHT
Do not install in a vertical, downward position. Position “On/Off” valves on downstream side.
Figure 12: Incorrect meter placement Figure 13: Position valves on downstream side
To minimize the possibility of partially-full pipe flows in horizontal, gravity or low pressure applications, create a pipe
arrangement that allows the sensor to remain full of liquid at all times.
Figure 14: Pipe positioned to keep water in sensor
Meter Location, Orientation and Applications
Page 14 March 2022MAG-UM-01272-EN-21