ENCODER PROTOCOL INTERFACE
The encoder protocol interface requires firmware version 1.10 or later. Reference BadgerMeter P/N 67354-003 to obtain a
firmware upgrade kit.
Enabling the meter as an encoder requires three settings, all within the advanced menu, to be configured.
• Totalizer Resolution – Selects the resolution of the display totalizer.
• Protocol Type – Selects the type of information to be transmitted to the encoder.
• Dial Type – Enables encoder and selects the number of significant totalizer digits to transmit.
Changing the protocol type automatically configures the necessary digital inputs/outputs. Manually changing the digital
inputs/outputs within the Input/Outputs menu is not allowed. Below is a wiring diagram for connecting an encoder to
the meter.
(Badger Meter P/N 69224-001)
Figure 38: Encoder interface
OTE: N When connected to an ORION® Cellular LTE endpoint, add a 15K resistor (BadgerMeter P/N 69224-001) to the meter
terminal block between terminal 1 (green wire) and terminal 8 (red wire) as shown to correct any potential meter
reading issues. The resistor is indicated by an arrow in the photo and in the drawing.
Encoder Protocol Interface
Page 57 March 2022 MAG-UM-01272-EN-21