EasyManua.ls Logo

Badger Meter ModMAG M Series - Sensor Type II Specifications; Sensor Type II Dimensionssensor Type II Specifications

Badger Meter ModMAG M Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M2000 Transmitter Dimensions
in. (mm)
3.90 (99)7.09 (180)
7.09 (180)
M20 (x3)
11.06 (281)
M2000-1
2.36 (60)
Ø 0.20 (5.2)
2.56 (65)
Sensor Type II Specications
The electromagnetic sensor type II is not only available in a number of different flange process connections (DIN, ANSI, JIS,
AWWA, and more) but also in a number of liners like hard rubber, PTFE, PFA, or Halar. The sensor is configurable with up to
4 electrodes for measuring, empty pipe and grounding electrodes. Available in sizes from DN 6 TO DN 2000 and nominal
pressures up to PN 100, the sensor type II is best suited for a variatey of applications in the industry and the water/waste
water industry.
Size 1/4…78 in. (DN 6…2000)
Flanges ANSI B16.5, AWWA, ISO 1092-1, JIS and more in carbon steel. Optional 304 or 316 stainless steel.
Nominal Pressure up to 1450 psi (100 bar)
Pressure Rating Line sizes 1/4…24 in. In accordance with ASME B16.5 Class 150 or Flange Rating Class 300
Line sizes 26…72 in. AWWA C-207 Class D or Class E Flange Rating
Protection CLass NEMA 4X (IP67), optional NEMA 6P (IP68)
Minimum Conductivity 5 µS/cm (20 µS/cm for demineralized water)
Liner Material
Hard/soft rubber 1…78 in. (DN 25…2000) 32…176° F (0…80° C)
PTFE 1/2…24 in. (DN 15…600) –40…302° F (–40…150° C)
Halar (ECTFE) 12 in. (DN 300) and larger –40…302° F (–40…150° C)
PFA 1/4…3/8 in. (DN 6…10)
Electrodes Materials
Hastelloy C (standard), Tantal
Platinum/Gold plated, Platinum/Rhodium
Housing Standard: Carbon steel welded; Optional: 316 or 304 stainless steel
Electrode Materials Standard: Hastelloy C22; Optional: 316 stainless steel, gold/platinum plated, tantalum, platinum/rhodium
Lay Length
1/4…3/4 in. (DN 6…20) 6.7 in. (170 mm)
1…2 in. (DN 25…50) 8.9 in. (225 mm)
2-1/2…4 in. (DN 65…100) 11.0 in. (280 mm)
5…8 in. (DN 125…200) 15.8 in. (400 mm)
10…14 in. (DN 250…350) 19.7 in. (500 mm)
16…28 in. (DN 400…700) 23.6 in. (600 mm)
30…40 in. (DN 750…1000) 31.5 in. (800 mm)
48…56 in. (DN 1200…1400) 39.4 in. (1000 mm)
64 in. (DN 1600) 63.0 in. (1600 mm)
72 in. (DN1800) 70.9 in. (1800 mm)
78 in. (DN2000) 78.7 in. (2000 mm)
Sensor Type II DimensionsSensor Type II Specications
The electromagnetic sensor type II is not only available in a number of different flange process connections (DIN, ANSI, JIS,
AWWA) but also in a number of liners like hard rubber, PTFE, PFA, or Halar. The sensor is configurable with up to 4 electrodes
for measuring, empty pipe and grounding electrodes. Available in sizes from DN 6 TO DN 2000 and nominal pressures up to
PN 100, the sensor type II is best suited for a variety of applications in the industry and the water/waste water industry.
Specications
Page 65 March 2022 MAG-UM-01272-EN-21

Table of Contents

Related product manuals