Input/Output Description Terminal
Analog Output 0…20 mA Resistive Load < 800 ohms
4…20 mA Resistive Load < 800 ohms
0…10 mA Resistive Load < 800 ohms
2…10 mA Resistive Load < 800 ohms
16 (+)
15 (–)
Digital Output 1 Passive maximum 30V DC, 100 mA
Active 24V DC, 50 mA (set Jumper JP1)
Maximum Frequency 10 kHz
1 (+) and 2 (–)
Digital Output 2 Passive maximum 30V DC, 100 mA
Active 24V DC, 50 mA (set Jumper JP2)
Maximum Frequency 10 kHz
3 (+) and 4 (–)
Digital Output 3 Passive Max 30V DC, 100 mA, 10 kHz
Solid State Relay 48V AC, 500 mA, 1 kHz
* Software configurable
10 (+) and 9 (–)
10 (+) and 11 (–)
Digital Output 4 Passive Max 30V DC, 100 mA, 10 kHz
Solid State Relay 48V AC, 500 mA, 1 kHz
* Software configurable
13 (+) and 12 (–)
13 (+) and 14 (–)
Digital Input 5…30V DC 8 (+) and 9 (–)
RS 232 RS232, configurable, Modbus RTU, Remote Menu, or
Primo 3.1 Emulation
7 GND
6 Rx
5 Tx
Communication Optional communications ports: Modbus, HART,
Profibus DP, M-Bus, BACnet MS/TP
Communication
Analog Output Wiring Diagram
Figure 22: Analog output wiring diagram
Conguring Input/Output (I/O)