EasyManua.ls Logo

Badger Meter ModMAG M Series - Specifications; Transmitter Specifications

Badger Meter ModMAG M Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SPECIFICATIONS
OTE: N DN represents nominal diameter in mm.
Transmitter Specications
Flow Range 0.10…39.4 ft/s (0.03…12 m/s)
Accuracy ± 0.20% m.v. ± 1 mm/s OIML/MID: 2…12 in. (DN50…300) with 0d up and 0d downstream ±1% ≥ 0.5 ft/s (0.15 m/s)
Repeatability ± 0.1%
Power Supply AC Power Supply: 100…240V AC (±10%); Typical Power: 20V A or 15W; Maximum Power: 26V A or 20W
Optional DC Power Supply: 9…36V DC; Typical Power: 10W; Maximum Power: 14W
Analog Output 4…20 mA, 0…20 mA, 0…10 mA, 2…10 mA (programmable and scalable)
Voltage sourced 24V DC isolated. Maximum loop resistance < 800 Ohms.
Digital Output Four total, configurable 24V DC sourcing active output (up to 2),100 mA total, 50 mA each; sinking open collector output (up to
four), 30V DC max, 100 mA each; solid-state relay (up to 2), 48V DC, 500 mA max, either polarity
Absolute Digital Encoded output for connectivity to AquaCUE or BEACON cellular endpoints
Digital Input Max 30V DC (programmable – positive zero return, external totalizer reset or preset batch start)
Frequency Output Scalable up to 10 kHz, open collector up to 1 kHz, solid-state relay
Misc Output High/low flow alarm (0…100% of flow), error alarm, empty pipe alarm, flow direction, preset batch alarm,
24V DC supply, ADE
Communication RS232 Modbus RTU; RS485 Modbus RTU, HART, Profibus DP and BACnet MS/TP require separate daughterboards
Pulse Width Scalable up to 10 kHz, passive open collector up to 10 kHz, active switched 24V DC. Up to two outputs (forward and reverse). Pulse
width programmable from 1…1000 ms or 50% duty cycle.
Processing 32-bit DSP
Empty Pipe Detection Field tunable for optimum performance based on specific application
Excitation Frequency 1 Hz, 3.75 Hz, 7.5 Hz or 15 Hz (factory optimized to pipe diameter)
Noise Dampening Programmable 0…30 seconds
Low Flow Cut-Off Programmable 0…10% of maximum flow
Galvanic Separation 250V
Fluid Conductivity Minimum 5.0 µS/cm (minimum 20 µS/cm for demineralized water)
Fluid Temperature With Remote Transmitter: PFA, PTFE & Halar 302° F (150° C)
With Meter-Mounted Transmitter: Rubber 178° F, (80° C), PFA, PTFE & Halar 212° F (100° C)
Ambient Temperature – 4…140° F (–20…60° C)
Relative Humidity Up to 90 percent non-condensing
Flow Direction Unidirectional or bidirectional two separate totalizers (programmable)
Totalization Programmable/resettable
Units of Measure Ounce, pound, liter, US gallon, imperial gallon, barrel, hectoliter, mega gallon, cubic meter, cubic feet, acre feet
Display 4 x 20 character display with backlight
Programming Three-button, external manual or remote
Transmitter Housing Cast aluminum, powder-coated paint
Mounting Meter mount or remote wall mount (bracket supplied)
Locations Indoor and outdoor
Meter Enclosure
Classification
Standard: NEMA 4X (IP67); Optional: Submersible NEMA 6P (IP68) depth of 2 m for 72 hr), remote transmitter required
Junction Box
Enclosure Protection
For remote transmitter option: powder-coated die-cast aluminum, NEMA 4 (IP67)
Cable Entries M20 cable glands (3)
Optional Stainless
Steel
Grounding Rings
Meter Size Thickness of one ring Thickness of one ring (DIN Flanges)
Up through 10 in. 0.135 in. (3.429 mm) 0.12 in. (3 mm)
12…78 in. 0.187 in. (4.750 mm) 0.12 in. (3 mm)
NSF/ANSI/CAN 61 and
372 Listed
Models with hard rubber liner, 4 in. size and larger; PTFE liner, all sizes
OIML R49-1
MID MI-001
AWWA C715
Size range: DN50…300 / 2…12 in.
Minimum straight inlet flow: 0 DN /outlet flow: 0 DN
Forward and reverse (bi-directional) flow on any orientation
Ratio (Q3/Q1) up to 250
Accuracy Class 1
Token Features Data Logging (Blue token); Store/Restore (Red token); Firmware Upgrade (Black token)
Specications
Page 64 March 2022MAG-UM-01272-EN-21

Table of Contents