Signal Cable Specication
OTE: N Only use signal cables delivered by BadgerMeter or corresponding cable in accordance with the
followingspecification.
Take maximum signal cable length between sensor and transmitter into account (keep distance as low as possible).
Distance With electrode idle Loop resistance
0…75 m 3 × (2 × 0.25 mm²) =< 160 Ω/km
>75…150 m 3 × (2 × 0.50 mm²) =< 80 Ω/km
PVC cable with pair and total shield
Capacity: wire/wire < 120 nF/km, wire/shield < 160 nF/km
Temperature range: –22…158° F (–30…70° C)