EasyManua.ls Logo

Badger Meter ModMAG M Series - Recommended Installation with Grounding Rings

Badger Meter ModMAG M Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
"X"
"X"
M4:1
Figure 16: Grounding electrode
Recommended Installation with Grounding Rings
IMPORTANT
BadgerMeter recommends the installation of a pair of grounding rings between the mating flanges at both ends of the meter. See
Figure 15 on page 15.
Connect the grounding straps to both of the grounding rings and to a good, solid earth ground. Grounding rings are available
in stainless steel. If your fluid is too aggressive for stainless steel, order a meter with the optional grounding electrode in a
material compatible with the fluid.
Meter Gaskets and Grounding