The following table demonstrates how the totalizers are displayed under various configurations of the Totalizer Resolution
(that is, resolution) and Dial Type. The non-shaded digits are transmitted as defined by the dial type.
For example, if the dial type is 4-dial and the resolution is 10000 then an arbitrary totalizer value of 99999999 is displayed
on the meter as 99990000 and 9999 is transmitted to the receiving application. In this configuration it takes 10000 units
(for example, USG) before the display totalizer is updated to a new value. For this example the display totalizer rolls over
to 00000000.
Dial
Type
Totalizer
Resolution
Display Digits
1 2 3 4 5 6 7 8 9 0
4 dial
10000 1 2 3 4 0 0 0 0
1000 1 2 3 4 0 0 0
100 1 2 3 4 0 0
10 1 2 3 4 0
1 1 2 3 4
0.1 1 2 3 . 4
0.01 1 2 . 3 4
0.001 1 . 2 3 4
0.0001 0 0 1 2 3 4
5 dial
10000 1 2 3 4 5 0 0 0 0
1000 1 2 3 4 5 0 0 0
100 1 2 3 4 5 0 0
10 1 2 3 4 5 0
1 1 2 3 4 5
0.1 1 2 3 4 . 5
0.01 1 2 3 . 4 5
0.001 1 2 . 3 4 5
0.0001 1 . 2 3 4 5
6 dial
10000 1 2 3 4 5 6 0 0 0 0
1000 1 2 3 4 5 6 0 0 0
100 1 2 3 4 5 6 0 0
10 1 2 3 4 5 6 0
1 1 2 3 4 5 6
0.1 1 2 3 4 5 . 6
0.01 1 2 3 4 . 5 6
0.001 1 2 3 . 4 5 6
0.0001 1 2 . 3 4 5 6
7 dial
10000 Not Applicable – Not enough display digits
1000 1 2 3 4 5 6 7 0 0 0
100 1 2 3 4 5 6 7 0 0
10 1 2 3 4 5 6 7 0
1 1 2 3 4 5 6 7
0.1 1 2 3 4 5 6 . 7
0.01 1 2 3 4 5 . 6 7
0.001 1 2 3 4 . 5 6 7
0.0001 1 2 3 . 4 5 6 7
8 dial
10000 Not Applicable – Not enough display digits
1000 Not Applicable – Not enough display digits
100 1 2 3 4 5 6 7 8 0 0
10 1 2 3 4 5 6 7 8 0
1 1 2 3 4 5 6 7 8
0.1 1 2 3 4 5 6 7 . 8
0.01 1 2 3 4 5 6 . 7 8
0.001 1 2 3 4 5 . 6 7 8
0.0001 1 2 3 4 . 5 6 7 8
Encoder Protocol Interface
Page 58 March 2022MAG-UM-01272-EN-21