OPERATION MANUAL
BALTECH VP-3470
vibrometer-balancer

Table of Contents

Questions and Answers:

Baltech VP-3470 Specifications

General IconGeneral
BrandBaltech
ModelVP-3470
CategoryMeasuring Instruments
LanguageEnglish

Summary

Safety Measures for BALTECH VP-3470

General Provisions for Safety

General safety guidelines for using the BALTECH VP-3470, including adherence to standards and intended use.

Personnel Safety Precautions

Ensuring operator safety during balancing, focusing on access to moving parts and safe operational practices.

Laser Safety Guidelines

Guidelines for safe operation of the device's laser tachometer, including precautions against direct eye exposure.

Installation of Trial and Correction Weights

Ensuring trial and correction weights are fixed securely and do not interfere with normal machine operation.

Technical Description of BALTECH VP-3470

Operation Conditions and Prestarting Procedures

Accelerometer Installation for Balancing and Diagnostics

Specific guidelines for sensor placement during balancing and diagnostic procedures for effective analysis.

Programs and Functions Overview

MEASUREMENTS Program

Program for performing various types of vibration measurements and analysis.

BALANCING Program

Program dedicated to performing rotor balancing procedures.

Measurements Functions

Overall Vibration Measurement

Performs overall vibration measurement, capturing RMS values across a frequency range.

Peak and Phase Measurement

Measures vibration amplitude and phase relative to a reference signal, crucial for balancing.

Performing Overall Measurements

Detailed procedure for performing and saving overall vibration measurements.

Peak and Phase Data Capture

Procedure for setting up and capturing peak and phase data.

Balancing Procedures

New Balancing Operation

Procedure to initiate and configure parameters for a new balancing operation.

Manual Input for Balancing

Allows manual entry of balancing parameters when automatic calculation is not used.

Re-balancing Process

Process for performing scheduled balancing of a machine using existing reports.

Influence Coefficient Method (ICM)

Utilizes the Influence Coefficient Method for efficient rotor balancing.

Step-by-Step New Balancing

Detailed steps for performing a new balancing procedure, including parameter setup and measurement.

Influence Coefficient Method (ICM) Application

Explains the ICM and its application in balancing, allowing for rotor balancing within a single run.

Reports Management

Maintenance and Care

Troubleshooting Potential Problems

Potential Problems and Correction Methods

Lists common device problems, their causes, and recommended corrective actions.