BALTECH VP-3470
Operation manual
Balancing 77
Procedure:
1. Select RE-BALANCING from the BALANCING program and press Enter (Figure 78).
Figure 80. Re‑balancing
2. Select a report and press Enter. The window with the installed weights will open
(Figure 80). 
Figure 81. Window with the installed weights
3. Press Enter to move to INITIAL RUN (Figure 64). 
4. Perform the actions described in the p. 4-11 (9.1. NEW BALANCING).  
9.4. Inuence Coefcient Method (ICM)
The ICM is a proportionality coefficient between the vibration and unbalance.