Figure 99. Module Definition
13. Select the desired connection in the Module Definition window. Each of the items in the Name list represents a fixed
grouping of input and output assembly instances:
Small Assemblies O>T PLC/iVu Plus Assembly 112 (0x70)
T>O PLC/iVu Plus Assembly 100 (0x64)
Large Assemblies O>T PLC/iVu Plus Assembly 113 (0x71)
T>O PLC/iVu Plus Assembly 101 (0x65)
BCR Only O>T PLC/iVu Plus Assembly 113 (0x71)
T>O PLC/iVu Plus Assembly 102 (0x66)
14. Select
INT as the data type.
Figure 100. Module Definition—Data Type
15. Click OK twice and download the program to the PLC.
iVu Plus BCR Gen2 Series Sensor
www.bannerengineering.com - Tel: + 1 888 373 6767 111