Numeric ID Text ID Description
10152 NOT_READABLE Attempt to get a value that is not readable
10153 NOT_WRITEABLE Attempt to set a value that is not writeable
10250 NOT_A_METHOD Method ID specified is not a method
10251 WRONG_ARGUMENT_COUNT Total method arguments specified do not match method
10252 COMMAND_NOT_FINISHED Attempt to issue command when a previous command has not
finished
10300 SET_WITH_ARGUMENT_TYPE_INVALID Item ID specified must be an item (not a group or method)
10301 DATA_VALUE_MISSING Command missing item's data value
10340 MINIMUM_VALUE_EXCEEDED New item value is below the minimum
10341 MAXIMUM_VALUE_EXCEEDED New items value is above the maximum
10350 ARGUMENTS_DETECTED Get command received with unneeded arguments
10351 GET_WITH_ARGUMENT_TYPE_INVALID Item ID specified must be an item (not a group or method)
10500 DATA_SET_EMPTY Data export operation returned no results
10900 SENSOR_NOT_READY Command specified requires the iVu BCR to be in the READY
state
10920 SENSOR_TYPE_NOT_ACTIVE Command specified belongs to a different sensor type
15000 VALUE_INVALID Text value is invalid / unknown
15050 VALUE_INVALID Text value is invalid - expecting True or False
15100 STRING_TOO_LONG String value specified exceeds maximum allowable length
20000 BARCODE_TIMEOUT Attempt to obtain Barcode result data when decoder has timed
out
20001 NO_BARCODES_FOUND Attempt to obtain Barcode result data when no barcodes were
found
20002 COMPARE_DATA_DISABLED Operation requires Barcode compare to be enabled
20003 COMPARE_MASK_INVALID Compare mask invalid. Expecting string of 1's and 0's with length
equal to compare data string
20004 NUMBER_TO_FIND_NOT_ONE Barcode number to find must be set to one for this operation
80000 REMOTE_DISPLAY_NOT_CONNECTED Remote Display must be connected to obtain this value
80001 REMOTE_DISPLAY_NOT_SUPPORTED This device does not have Remote Display capability
80100 COMMAND_MODE_EXPECTED The Trigger Mode must be set to Command perform this operation
80101 COMMAND_TIMED_OUT The command timed out before finishing
80102 TRIGGER_REQUIRED Access to the specified data requires a triggered inspection
80103 TRIGGER_NOT_GATED Command requires a active Gated Trigger
80150 COMMAND_TIMED_OUT The command timed out before finishing
80200 SYSTEM_ERROR_NOT_ACTIVE A System Error must be active to execute this command
13.5 iVu BCR Discovery Protocol
The iVu BCR Discovery Protocol is a method to dynamically discover Banner iVu BCR devices on an Ethernet network.
The goal is to both be able to find a device and, if necessary, change the IP address of that device so that it is on the same
subnet as the controlling PC. This is done without requiring the PC to change its IP address or using anything more than an
Ethernet cable connected to the device.