For all subsequent triggers, when the sensor reads the barcode data, it compares it against this reference data.
6.3.1 Remote Teach
The Remote Teach function is a method of remotely updating inspection parameters while the iVu BCR is running. The
sequence of events for executing a Remote Teach are:
1. With the device Ready (see
Installation Instructions
(p. 18)), pulse the Remote Teach line.
2. The iVu BCR recognizes that the Remote Teach line has been pulsed and waits for the next valid trigger.
3. At the next valid trigger, Ready goes inactive (the Green Ready LED shuts OFF), and the iVu BCR acquires a new
image.
When a Remote Teach occurs, the data of the
first read barcode is saved as Data Compare input. Inspections executed on
the next trigger use the new data for comparison with subsequently read barcodes. If the previous input data contained any
masked characters, Remote Teach retains the masked characters only if the new data is of the same length as the previous
input data. If the length does not match, masking is removed.