11.6.3 Output Type
Main Menu > System > Discrete I/O > Output Type
Select NPN to
configure the device's outputs to sink current. Select PNP to configure the device's output for source
current.
11.6.4 Output 1
Main Menu > System > Discrete I/O > Output 1
Output 1 can be
configured for Inspection Pass, Inspection Fail, Read, No Read, Match, No Match, Missed Trigger, or
System Error.
A Read condition is when the configured number of barcodes are found in a scan. These barcodes must be error-
free.
A No Read condition is when the configured number of barcodes are not found in a scan sequence. This will not
occur in Continuous Scan mode.
If Data Compare is disabled, Inspection Pass and Inspection Fail are the same as Read and No Read.
If the sensor is using Data Compare, Inspection Pass indicates that a good barcode was found, and the data
compared.
If the sensor is using Data Compare, Inspection Fail indicates that either no good barcode was found, or the data
did not compare.
A Match condition occurs when the required number of barcodes are found and the compare is successful.
A No Match condition occurs when the required number of barcodes are found, but the compare is not successful.
A Missed Trigger condition occurs when a trigger is received while the sensor is busy inspecting the pervious image.
This output signal is set to the active state. This signal is reset up on resetting the History on the statistics page.
A System Error condition occurs when a fatal error is detected on the sensor. This output signal is set to the active
state. This signal can be reset upon resetting the History on the statistics page, or executing a ClearSystemError
command through command channel.
The default setting is Inspection Pass and Latched for Output 1. If Pulsed is selected, the default Pulse width is 50 ms.
Note: For Latched the signal is active until the results of an inspection cause a change in the signal
output.
11.6.5 Output2 and Output3
Main Menu > System > Discrete I/O > Output 2
Main Menu > System > Discrete I/O > Output 3
Output 2 and Output 3 can be configured in a similar way as Output 1.
The default setting for Output 2 is Fail and Latched. The default setting for Output 3 is Pass and Latched.