Figure 101. Download to the PLC
The connection looks like the one in
Figure 101
(p. 112).
14.4.8 RSLogix5000 Configuration
To create an implicit Class 1 configuration to the iVu BCR using EtherNet/IP when using a ControlLogix family PLC,
configure the iVu BCR as a “Generic Ethernet Module” under the ENET_MODULE. The following is a sample setup of a
Banner device:
1. Add a generic Ethernet module to the PLC's Ethernet card.
a. Click New Module.
Figure 102. Add Ethernet Module
b. Click Communications, then Generic Ethernet Module.
iVu Plus BCR Gen2 Series Sensor
112 www.bannerengineering.com - Tel: + 1 888 373 6767