BCR_RESULT Command Group
Command Group Item Description
Get BCR_RESULT Count The total number of barcodes found. The most recent inspection value
is used. Access to this value requires a valid trigger.
Get BCR_RESULT Data The decoded barcode data strings. Each string starts and ends with the
double quote character. Multiple values are separated by the field
delimiter The most recent inspection value is used. Access to this value
requires a valid trigger.
Get BCR_RESULT Type The decoded barcode symbol type(s). Multiple values are separated by
the field delimiter The most recent inspection value is used. Access to
this value requires a valid trigger.
Example
>> Get BCR_Result Data
<< OK\x0D\x0A
>> "mydata"\x0D\x0A
BCR_HISTORY Command Group
Command
Group Item Description
Get BCR_HISTORY MinCount Indicates the minimum number of barcodes read for the active
inspection This value is cleared (reset) whenever history is cleared. This
value is cleared (reset) when the device starts up or is rebooted.
Get BCR_HISTORY MaxCount Indicates the maximum number of barcodes read for the active
inspection This value is cleared (reset) whenever history is cleared. This
value is cleared (reset) when the device starts up or is rebooted.
Example
>> Get BCR_History MinCount
<< OK\x0D\x0A
>> 1\x0D\x0A
13.4.5 Command Channel Command Status Register
The command status register will confirm receipt of a command by reflecting the exact command ID received, regardless of
whether the command was valid or not.
13.4.6 Command Channel Error Codes
Table 9: Plus BCR Command Channel Error Codes
Numeric ID
Text ID Description
00000 SUCCESS Command processed successfully
10000 EMPTY_FRAME_RECEIVED Indicates that the request was empty. The command channel
requires a command, any arguments, and an end-of-frame
delimiter.
10001 COMMAND_NOT_RECOGNIZED The command specified is not recognized
10100 GROUP_MISSING A Group ID must be specified immediately after the command
10101 GROUP_NOT_FOUND The specified Group ID is invalid / unknown
10102 GROUP_ITEM_MISSING A Group Item ID must be specified immediately after the Group ID
10103 GROUP_ITEM_NOT_FOUND The specified Group Item ID is invalid / unknown