To Address = IP address of the iVu BCR
Figure 118. MultiHop tab: IP address of the iVu BCR is entered here
14.6.2 Inputs to iVu BCR (Outputs from PLC)
The registers below are used by the PLC to push values to the iVu BCR device. MSG (message) commands are used to
write (N14) to the iVu BCR.
See
Barcode Type Numeric Codes
(p. 105) for additional information.
Table 21: PCCC PLC Output Registers (iVu BCR Inputs, N14 Table)
WORD # WORD NAME DATA TYPE
0 Input Bits Register (see
Input and Output Flags
(p. 129)) 16-bit integer
1-2 Product Change Number 32-bit integer
3-49
reserved
32-bit integer
50 Command ID 16-bit integer
51 Command Parameter Int16 16-bit integer
52-53 Command Parameter Int 32 32-bit integer
54-55 Command Parameter Float
56-57 Command Parameter String Length 32-bit integer
58-107 Command Parameter String 100-Byte Array
108
reserved
16-bit integer
109-110 BCR String/Mask Length 32-bit integer
111-120 BCR String/Mask 200-Byte Array
211-239
reserved
16-bit integer
14.6.3 Outputs from iVu BCR (Inputs to PLC)
The registers below are used to send output values from the iVu BCR device to the PLC. MSG (message) commands are
used to read (N7) from the iVu BCR.
iVu Plus BCR Gen2 Series Sensor