Table 22: PCCC PLC Input Registers (iVu BCR Outputs, N7 Table)
WORD # WORD NAME DATA TYPE
0 Input Bits ACK Register (see
Input and Output Flags
(p. 129)) 16-bit integer
1 Output Bits Register (see
Input and Output Flags
(p. 129)) 16-bit integer
2-3 Error Code 32-bit integer
4-5 Inspection Number 32-bit integer
6-7 Iteration Count 32-bit integer
8-9 Pass Count 32-bit integer
10-11 Fail Count 32-bit integer
12-13 Missed Triggers 32-bit integer
14-15 Current Inspection Time Float
16 Sensor Pass/Fail Coil 16-bit integer
17-29
reserved
16-bit integer
30-52 Inspection Name 2-Word length + 20 Unicode characters
53-54 Frame Number 32-bit integer
55 Sensor Type ID 16-bit integer
56 Barcode Count 16-bit integer
57 Barcode-1 Type 16-bit integer
58 Barcode-1 Actual Decoded Data Length 16-bit integer
59-60 Barcode-1 Data Array Length 32-bit integer
61-162 Barcode-1 Data Array 100 Byte Array
163-170
reserved
16-bit integer
171 Command Status 16-bit integer
172 Command Response Int16 16-bit integer
173-174 Command Response Int32 32-bit integer
175-176 Comand Response Float
177-178 Command Response Length 32-bit integer
179-228 Command Response Data 100 Byte Array
229-239
reserved
16-bit integer
240 Barcode Count 16-bit integer
241 Barcode-1 Type 16-bit integer
242 Barcode-1 Length 16-bit integer
243-260 Barcode-1 Data 32-bit length + 32-byte array
261 Barcode-2 Type 16-bit integer
262 Barcode-2 Length 16-bit integer
263-280 Barcode-2 Data 32-bit length + 32-byte array
281 Barcode-3 Type 16-bit integer
282 Barcode-3 Length 16-bit integer
283-300 Barcode-3 Data 32-bit length + 32-byte array
301 Barcode-4 Type 16-bit integer
302 Barcode-4 Length 16-bit integer
iVu Plus BCR Gen2 Series Sensor
128 www.bannerengineering.com - Tel: + 1 888 373 6767