Figure 179. Ethernet I/O Status Screen
5. On the PC attached to your LAN, open the Command window. To do this, click Start > Run, enter cmd, and click
OK. A command window displays.
Figure 180. Command Window
6. Enter a ping command specifying the iVu BCR IP address as an argument. You should see a series of responses
from the iVu BCR.
Figure 181. Command Window with Responses from the iVu BCR
You should also see the Packets Received and Packets Sent count on the Ethernet I/O Status screen in the camera
increment by at least 4.
7. If the output of the ping command shows request timeouts, try the following:
• Verify that the camera is located on the correct subnet, has the correct IP address, and is connected to the
correct switch or router
iVu Plus BCR Gen2 Series Sensor
170 www.bannerengineering.com - Tel: + 1 888 373 6767