PROFINET
Discovering iVu BCR Devices
The Siemens TIA Portal (v13) software discovery and
configuration protocols are used to discover iVu BCR devices on a
network.
1. Start the Siemens TIA Portal (v13) software.
2. Click Open an existing project.
3. Select a project and open it.
4. Click Devices & networks after the project has been uploaded.
5. Click
Configure networks.
6.
Click the Accessible devices icon.
The Accessible devices window opens.
7. Select an interface connection in the Type of the PG/PC interface list.
8. Select an interface connection in the PG/PC interface list.
Figure 188. PG/PC Interface
The PC scans the network for PROFINET
®
devices. If the device you are looking for is not present, check the
cabling.
Example of Scanning Results
Under Online status information, the scan shows that three devices were found.
Figure 189. Select Device—Online Status Information
Accessing the iVu BCR Device's Communication Logs
PROFINET
®
communication activity is recorded in the iVu BCR device's communication logs. Use these instructions to
access the iVu BCR device's communication logs via the display.
1. Go to Main Menu > Logs > Communication Logs > Industrial Ethernet > View Logs.