4. Set Trigger to Command. Go to Main Menu > Imager > Trigger , and from the drop-down list select Command.
5. Issue a trigger command as follows:
>> do trigger\x0D\x0A
<< OK\x0D\x0A
6. Check that the inspection passed.
>> get inspection status\x0D\x0A
<< OK\x0D\x0A
<< Pass\x0D\x0A
7. Get the barcode data read by the iVu sensor.
>> get bcr_result\x0D\x0A
<< OK\x0D\x0A
<< "0043000011201"x0D\x0A
How to Modify Barcode Compare Data Using the Command Channel
1. Go to Main Menu > System > Sensor
Configuration > Serial I/O.
2. Click Channel Mode.
3. In the Channel Mode dialog, select Command from the drop-down list.
4. Set Trigger to Command. Go to Main Menu > Imager > Trigger , and from the drop-down list select Command.
5. Set the compare data.
>> set bcr_input comparedata "0043000011201"\x0D\x0A
<< OK\x0D\x0A
6. Trigger the sensor.
>> do trigger\x0D\x0A
<< OK\x0D\x0A
7. Check that the inspection passed.
>> get inspection status\x0D\x0A
<< OK\x0D\x0A
<< Pass\x0D\x0A
iVu Plus BCR Gen2 Series Sensor
www.bannerengineering.com - Tel: + 1 888 373 6767 85