12. Servicing
12.4.3 Readjustment of the plungers
CAUTION: Do NOT adjust the plungers on the DMD assembly, if small convergence drifts have to be corrected
only.
For extreme convergence adjustments, possible in case after the replacement of a DMD assembly, a readjust-
ment of the plungers can be necessary.
Convergence screw is end of course
1. Turn the plunger (A ) a few turns counterclockwise.
A
B
Image 12-23
Readjustment plunger
2. Continue with the fine convergence adjustment
Convergence screw senses no resistance
1. Turn the plunger clockwise until resistance is s ensed again.
A
B
Image 12-24
Readjustment plunger
2. Continue with the fine convergence adjustment
116
R59770091 DP-1500 06/01/2009