6. Lamp & lamp house
3. Release the x enon bulb lamp from its socket by remov ing the hexagon socket head cap screw and plane was her as illustrated.
Use a 5 mm Allen wrench.
Image 6-6
4. Slide the white anode soc ket, w hich is c onnected via a thick wire with the xenon bulb lamp, upwards away from its position and
then remove the x enon bulb lamp with anode socket from the lamp h ouse.
Image 6-7
5. Place the xenon bulb lamp into a protective container or wrap a protective cloth around the xenon bulb lamp.
6. Remov e the anode wire lug from the a
node socke t. Us e for that two open ended spanners of 17 mm. Hold fast the nut N1 with
one spanner while releasing the nut N2 with the other spanner. Note that a plane washer ( W1 & W2) is pr ovided on both sides
of the anode wire lug (L).
50 R59770091 DP-1500 06/01/2009