6. Lamp & lamp house
2,5 Nm
A
Image 6-17
11.Reinstall the side cover of the lamp house as illustrated.
Note: Please ensure that the thumb screws turning wires are ash with the cover or interference will occur while inserting the
lamp house into the projector.
Image 6-18
CAUTION: The “LAMP INFO” parameters which are stored on a chip inside the lamp house MUST be updated
after each installation of an xenon bulb lamp inside the lamp house. Neglecting this update will result in poor
performance and short life time of the xenon bulb lamp. See procedure "Resetting the lamp parameters", page
59.
A realignment of the xenon bulb lamp in its reector is required after the installation of the xenon bulb lamp
in the lamp house. See procedure "Realignment of the lamp in its reector", page 60.