Basler pilot 105
Example
Assume that you are using a piA640-210gm camera set for an exposure time of 2000 µs and for
600 x 400 resolution. Also assume that you have checked the value of the Device Current
Throughput parameter, the Payload Size parameters and found them to be 110000000 and 240000
respectively, and the averaging feature is not used.
Formula 1:
Max Frames/s = 248.4 frames/s
Formula 2:
Max Frames/s = 488.5 frames/s
Formula 3:
Max Frames/s = 458.3 frames/s
Formula one returns the lowest value. So in this case, the limiting factor is the sensor readout time
and the maximum allowed acquisition frame rate would be 248.4 frames per second.
Max Frames/s
1
400 8.76 µs×()521.17 µs+
-------------------------------------------------------------------------=
Max Frames/s
1
2000 µs 46.99 µs+
---------------------------------------------------=
Max Frames/s
110000000
240000
------------------------------=