9.6.5 Changing the cartridge of the purifier
When the system has been used for the maximum permissible number of operating
hours, change the cartridge as follows.
Vacuum packing of the cartridge is undamaged.
Special filter spanner (part of the scope of supply).
A clean cloth is provided.
A suitable grease for breathing air application is available, see Chapter 9.3.3
Lubricant, Page 85.
1.
De-pressurise the unit, see Chapter 9.6.3 De-pressurising the unit, Page 99 .
2.
In case of filter systems with SECURUS filter monitoring: Disengage union nuts
detach the connector of the cable from the coupling.
OPERATING MANUAL Maintenance | 9
28.08.2019
A_002_en
103/150