4.1.5 Technical data PE 300-TB
Category and unit Value
Performance characteristics
Medium Air
Intake pressure atmospheric
Operating pressure max. [bar] 330
Blow-off pressure, final pressure safety valve
[bar]
225 / 330
Switch-off pressure [bar] 220 / 320
Setting pressure, pressure maintaining/non-
return valve [bar]
180
Setting times of automatic condensate drain
(option), interval [min] / duration [s]
15 / 6
Compressor block IK120
Delivery volume [l/min] measured using cylin-
der filling (10 l) from 0 to 200 bar, ± 5%
300
Speed [rpm]
1800 ±20
Drive motor type Petrol engine
Power rating, drive motor [kW] 9.0
Power consumption [kW] 6.5
Ambient conditions
Maximum permissible ambient temperature
[°C]
+5 ... +45
Location [m above sea level] 0 ... 1000
Explosion protection no
Maximum permissible inclination of the com-
pressor
15°
Weights and measures
Dimensions standard unit (L x W x H) [mm] 1270 x 592 x 650
Weight [kg] 145
Operating and auxiliary materials
Oil see Chapter 9.3.4 Lubrication oil, Page 86
Emissions
Noise pressure level [dB(A)] in accordance
with DIN EN ISO 2151 at 1m distance
92
Noise pressure level [dB(A)] 106
4 | Technical data OPERATING MANUAL
46/150
A_002_en
28.08.2019