9.5 Maintenance activities - Intake section
9.5.1 Replacing the suction filter
The maintenance intervals are dependent on the condition of the air being drawn
in. If there is a lot of dust it may be necessary to carry out maintenance monthly or
weekly.
1
1
Fig. 24 Suction filter
1 Filter element
WARNING
Danger of poisoning due to contaminated breathing air!
Ensure cleanliness and hygiene.
Only use cleaning agents and sealant that are suitable for breathing air.
1.
Remove the cover.
2.
Remove filter element.
3.
Brush off or blow out the filter element dry and change it if necessary.
4.
Clean the filter housing with a damp cloth. Make sure that no dust gets into
the intake tube.
5.
Insert new filter element.
6.
Place the cover.