4.1.2 Technical data PE 200-TE
Category and unit Value
Performance characteristics
Medium Air
Intake pressure atmospheric
Operating pressure max. [bar] 330
Blow-off pressure, final pressure safety valve
[bar]
225 / 330
Switch-off pressure [bar] 220 / 320
Setting pressure, pressure maintaining/non-
return valve [bar]
180
Setting times of automatic condensate drain,
interval [min] / duration [s]
15 / 6
Compressor block IK120
Delivery volume [l/min] measured using cylin-
der filling (10 l) from 0 to 200 bar, ± 5%
200
Speed [rpm] 1250 ±20
Drive motor type Three phase AC squirrel-cage motor
Ambient conditions
Maximum permissible ambient temperature
[°C]
+5 ... +45
Location [m above sea level] 0 ... 1000
Explosion protection no
Maximum permissible inclination of the com-
pressor
15°
Weights and measures
Dimensions [mm] 1100 x 500x 570
Weight [kg] 120
Operating and auxiliary materials
Oil see Chapter 9.3.4 Lubrication oil, Page 86
Emissions
Noise pressure level [dB(A)] in accordance
with DIN EN ISO 2151 at 1m distance
83
Noise level [dB(A)] 97
Electricity
Standard operating voltage [V] 400
Standard frequency [Hz] 50
OPERATING MANUAL Technical data | 4
28.08.2019
A_002_en
43/150