6.2 Installing the unit
6.2.1 Installing the unit
DANGER
Danger of poisoning due to pollutants in breathing air!
Units with petrol engines should never be operated in closed rooms!
When filling breathing air cylinders using petrol units, each filled cylinder must
be CO checked since, even with careful handling and the use of special car-
tridges with a catalytic converter (CO filter cartridges), contamination of the
compressed air cannot be ruled out.
Never operate the unit in the vicinity of open flames.
WARNING
Danger of injuries due to improper assembling!
Improper assembling can result in personal and material damage.
Install and connect the unit properly and in accordance with the relevant
guidelines.
1.
Install the unit such that it is not exposed to direct sunlight.
2.
Maintain adequate distance (at least 2 metres) from flammable objects.
3.
Ensure that the machine can be accessed from all sides.
4.
Ensure that there is 50 cm of space around the machine for fitting and disas-
sembling the lines as well as for maintenance work and disassembling and as-
sembling the machine.
5.
On machines with combustion engines maintain a minimum distance of 1 me-
tre around the cooling air inlet and the exhaust from the engine.
6.
The unit should be installed in such a way that the cooling fan on the compres-
sor can draw in cool air from the outside. For this, install the unit as close as
possible to the intake opening.
7.
Install the unit in such a way that intake of heated up or even hot air is avoi-
ded.