7.2.1 Switching on the unit
1.
On units without automatic condensate drain: Open the condensate drain
cocks to allow the pressure to dissipate and to allow the engine to start under
zero load.
The compressor is automatically unloaded on units with automatic condensate
drain.
2.
For units with motor protection switch: Set switch to I.
- Or -
For units with compressor control system: Set the main switch to I and push
the green start button.
- Or -
For units with petrol engine: Open the fuel tap. Set ignition switch to I. Set the
choke on the petrol engine to Start and start the engine using the pull starter.
As soon as the engine starts and is running smoothly, set the choke to Run.
4
1
2
5
3
Fig. 16 Starting units with petrol engine
1 Choke 4 Petrol engine
2 Pull starter 5 Ignition switch
3 Fuel tap
3.
Close the condensate drain cocks and run the unit to final pressure.
4.
Check the final pressure safety valve and pressure gauge.
5.
Open the condensate drain cocks and drain the condensate when the final
pressure is reached.
7 | Commissioning and operation OPERATING MANUAL
68/150
A_002_en
28.08.2019