3.3.2 Filling equipment
Fig. 11 Filling equipment
1 Filling cock 3 International bracket connection,
200 bar
2 Filling connection 4 Filling pressure gauge
3.4 Operating modes
3.4.1 Manual
After switching the compressor on manually, this must then also be switched off
again manually.
3.4.2
Semi-automatic
After the compressor is switched on manually, it switches off automatically on
reaching the switch-off pressure. It needs to be restarted manually. It can be
switched off manually at all times.
3 | Product description OPERATING MANUAL
40/150
A_002_en
28.08.2019