7.1.5 Preparing for the operation with B-TIMER
1.
Ensure that the compressor’s pressure retention valve is set to 160 bar and
that it is functioning correctly. Otherwise, the operation detection and the dis-
play of filter capacity do not function correctly.
2.
Ensure that the settings in the setup menu are correct. Otherwise, the B-TIM-
ER can only be used as an operating hours counter.
3.
Reset all maintenance counters, see Resetting the B-TIMER, Page 72. Other-
wise, incorrect maintenance intervals are shown since storage periods are not
taken into account.
7 | Commissioning and operation OPERATING MANUAL