4.3.3 Technical data filter system P41
Category and unit Value
Number of cartridge filters 1
Operating pressure max. [bar] 350 / 420 / 550
Operating pressure min. [bar] 90
Deployment temperature range [°C] +5 ... +50
Residual water content max. [mg/m
3
]
10
Residual oil content max. [mg/m
3
]
0.1
Residual carbon monoxide (CO) content*
max. [mg/m
3
]
5
Max. permissible number of load cycles See accompanying pressure equipment oper-
ating instructions
* Only when using filter cartridges with CO removal and a maximum CO concentra-
tion of 25 ml/m
3
in the intake area of the compressor.
4.4 Technical data Motor
For technical data about the motor, see the motor rating plate.
4 | Technical data OPERATING MANUAL