11.4.3 Filter cartridge 80100
Cartridge service life [hours]
Filling pressure p = 200 bar Delivery volume [l/min]
Ambient tem-
perature tU
[°C]
Temperature
in final sepa-
rator tAb [°C]
150 200 250 320
10 20 - 24 80 - 63 60 - 48 48 - 38 37 - 30
15 25 - 29 60 - 48 45 - 36 36 - 29 28 - 23
20 30 - 34 45 - 37 34 - 28 27 - 22 21 - 17
25 35 - 39 35 - 28 26 - 21 21 - 17 16 - 13
30 40 - 44 27 - 22 20 - 17 16 - 13 13 - 10
35 45 - 49 21 - 17 16 - 13 13 - 10 10 - 8
40 50 - 54 17 - 14 12 - 10 10 - 8 8 - 6
Cartridge service life [hours]
Filling pressure p = 300 bar Delivery volume [l/min]
Ambient tem-
perature tU
[°C]
Temperature
in final sepa-
rator tAb [°C]
150 200 250 320
10 20 - 24 120 - 95 90 - 71 72 - 57 56 - 45
15 25 - 29 90 - 72 67 - 54 54 - 43 42 - 34
20 30 - 34 68 - 55 51 - 41 41 - 33 32 - 26
25 35 - 39 52 - 43 39 - 32 31 - 26 25 - 20
30 40 - 44 40 - 33 30 - 25 24 - 20 19 - 16
35 45 - 49 32 - 26 24 - 20 19 - 16 15 - 12
40 50 - 54 25 - 21 19 - 16 15 - 12 12 - 10
Number of cylinder fillings n according to cylinder size [l]
Ambient tempera-
ture tU [°C]
Temperature in fi-
nal separator tAb
[°C]
Air humidity, satu-
rated X [g/m
3
]
7 l 10 l 12 l
10 20 - 24 17.31 - 21.80 513 - 408 359 - 285 299 - 238
15 25 - 29 23.07 - 28.79 385 - 309 270 - 216 225 - 180
20 30 - 34 30.40- 37.63 292 - 236 205 - 165 171 - 138
25 35 - 39 39.65 - 48.64 224 - 183 157 - 128 131 - 107
30 40 - 44 51.21 - 62.41 174 - 142 121 - 100 101 - 83
35 45 - 49 65.52 - 79.28 136 - 112 95 - 78 79 - 65
40 50 - 54 83.08 - 99.85 107 - 89 75 - 62 62 - 52
OPERATING MANUAL Appendix | 11
28.08.2019
A_002_en
131/150

Table of Contents