Fig. 14 Plug of solenoid valve coil
1 Screw to pull out the plug 2 Solenoid valve coil
7.
Remove the plug from the solenoid valve coil and allow the compressor to run
with open condensate drain valves for 10 minutes in order to ensure perfect
lubrication before starting to build up the pressure.
- Or -
On units without automatic condensate drain, allow the compressor to run for
10 minutes with the condensate drain cocks open.
Fig. 15 Opening/closing the condensate drain cocks
8.
After 10 minutes, fit the plug of the solenoid valve coil again.
- Or -
Close all the condensate drain cocks.
9.
Observe the pressure build-up in the unit properly. If there are any irregulari-
ties, switch off the unit immediately and locate and rectify any errors or get in
touch with the BAUER customer service department, see Chapter 1.1.1 Con-
tact data BAUER KOMPRESSOREN, Page 9.
OPERATING MANUAL Commissioning and operation | 7
28.08.2019
A_002_en
63/150